Nitric Acid Flow Meter
2024-07-22
Nitric Acid Flow Meter is a kind of instrument specially used to measure the flow of highly corrosive liquid such as nitric acid. In the petroleum, chemical, metallurgy and other industrial sectors, especially involving the production and use of nitric acid, nitric acid flowmeters play a vital role.
Which flowmeters can be used as nitric acid flowmeters? The common nitric acid flowmeters on the market are mainly electromagnetic flowmeters and ultrasonic flowmeters.
Electromagnetic Flow Meter: This flowmeter uses the principle of electromagnetic induction to measure the flow rate of the fluid without contact, so it does not affect the flow of the fluid. It has high accuracy and long-term stability, has good corrosion resistance to concentrated acids, and is suitable for concentrated acid liquid flow measurement in the range of 15mm to 3000mm pipe diameter.
Ultrasonic Flow Meter: This flowmeter uses the relationship between the propagation speed of ultrasonic waves in the fluid and the flow rate, the flow rate of the fluid is measured by the ultrasonic probe, and then the flow rate is calculated by the cross-sectional area of the fluid pipeline. The measurement principle is clear, the structure is simple, the precision is high, the fluid type is basically no requirements, so it is also suitable for the measurement of concentrated acid pipeline flow.
These two flowmeters are a good choice for measuring nitric acid flow, the specific choice of which type, according to the actual application scenario, accuracy requirements, fluid characteristics and other factors. When choosing, it is recommended to consult a professional flowmeter supplier or engineer to ensure that the most suitable flowmeter type is selected.
The following mainly introduces the application of electromagnetic flowmeter in the measurement of nitric acid
1. Sensor Overview
The sensor part of the nitric acid flowmeter is usually made of corrosion-resistant materials to ensure stable operation in highly corrosive environments. A measuring electrode and a magnetic field generating device are designed inside the sensor to determine the flow rate by measuring the induced potential difference generated by the flow of nitric acid in the magnetic field.
2. How it works
The operating principle of the nitric acid flowmeter is based on Faraday's law of electromagnetic induction. When nitric acid flows in a magnetic field, it creates an induced potential difference on the measuring electrode. This induced potential difference is proportional to the flow rate of nitric acid, and by measuring this potential difference, the flow rate of nitric acid can be accurately calculated.
3. Structural characteristics
The structural characteristics of nitric acid flowmeter are mainly reflected in the following aspects:
1) Corrosion-resistant material: The sensor part is made of corrosion-resistant material to adapt to the strong corrosive environment.
2) Accurate measurement: Determine the flow rate by measuring the potential difference, and the measurement accuracy is high.
3) Stable and reliable: the internal structure of the sensor is simple, reasonable design, stable and reliable work.
4) Easy maintenance: the sensor part can be disassembled for easy cleaning and maintenance.
4. Measuring range
The measuring range of the nitric acid flowmeter depends on the specific model and specification, generally covering the flow range from a few milliliters per second to dozens of cubic meters per hour. The user should determine the appropriate model according to the actual required flow range when selecting.
5. Accuracy level
The accuracy level of nitric acid flowmeters is generally divided according to international standards, such as 0.5, 1.0, 1.5 and so on. The accuracy level indicates the accuracy and stability of the measurement results, and the user should choose the appropriate accuracy level according to the actual needs.
6. Installation and commissioning
The installation and commissioning of the nitric acid flowmeter should follow the following steps:
1) Select the appropriate installation position to ensure that the sensor is perpendicular to the fluid flow direction and away from strong magnetic field interference.
2) When installing the sensor, ensure that the sensor is aligned with the pipeline to avoid eddy current and bias.
3) Connect the cable between the sensor and the transmitter to ensure that the connection is reliable and meets safety requirements.
4) Calibrate and debug the flowmeter to ensure accurate measurement. During calibration, standard flowmeters or standard solutions can be used for comparison and adjustment.
7. Use and maintenance
In order to ensure the long-term stable operation of the nitric acid flowmeter, the following use and maintenance work is required:
1) Regularly check the connection of the sensor and cable to ensure its safety and reliability. If it is loose or damaged, it should be fastened or replaced in time.
2) Regularly clean the inner wall and electrode of the sensor to remove dirt and impurities. When cleaning, use the appropriate cleaning agent, and avoid using too rough cleaning tools, so as not to damage the sensor surface.
3) Check the working condition of the converter regularly to ensure its normal operation. If any abnormal situation is found, it should be stopped in time to check and eliminate the fault.
4) Avoid the operation of strong magnetic field interference near the sensor, so as not to affect the measurement accuracy.
8. Fault diagnosis and troubleshooting
When the nitric acid flowmeter fails, it can be diagnosed and eliminated by the following methods:
1) Check the connection of the sensor and cable to ensure that the connection is reliable. If it is loose or damaged, it should be fastened or replaced in time.
2) Check whether there is dirt or impurities on the inner wall and electrode of the sensor, and clean it if necessary. Re-calibrate after cleaning to ensure measurement accuracy.
3) Check the working condition of the converter, if there is an abnormal need to repair or replace. During maintenance, check whether components such as the power supply and circuit board are damaged or aged.
4) If the above methods can not solve the problem, you can contact professionals for further maintenance and debugging. During the maintenance process, care should be taken to protect the sensor and converter parts to avoid further damage.
By following the above methods of use and maintenance, fault diagnosis and elimination, the long-term stable operation of the nitric acid flowmeter can be ensured, and accurate and reliable flow data support can be provided for the production and use of nitric acid.
If you want to know more about the flow meter or flow meter selection, please consult the Aister flow meter manufacturer email: sales@aistermeter.com for help.
Which flowmeters can be used as nitric acid flowmeters? The common nitric acid flowmeters on the market are mainly electromagnetic flowmeters and ultrasonic flowmeters.
Electromagnetic Flow Meter: This flowmeter uses the principle of electromagnetic induction to measure the flow rate of the fluid without contact, so it does not affect the flow of the fluid. It has high accuracy and long-term stability, has good corrosion resistance to concentrated acids, and is suitable for concentrated acid liquid flow measurement in the range of 15mm to 3000mm pipe diameter.
Ultrasonic Flow Meter: This flowmeter uses the relationship between the propagation speed of ultrasonic waves in the fluid and the flow rate, the flow rate of the fluid is measured by the ultrasonic probe, and then the flow rate is calculated by the cross-sectional area of the fluid pipeline. The measurement principle is clear, the structure is simple, the precision is high, the fluid type is basically no requirements, so it is also suitable for the measurement of concentrated acid pipeline flow.
These two flowmeters are a good choice for measuring nitric acid flow, the specific choice of which type, according to the actual application scenario, accuracy requirements, fluid characteristics and other factors. When choosing, it is recommended to consult a professional flowmeter supplier or engineer to ensure that the most suitable flowmeter type is selected.
The following mainly introduces the application of electromagnetic flowmeter in the measurement of nitric acid
1. Sensor Overview
The sensor part of the nitric acid flowmeter is usually made of corrosion-resistant materials to ensure stable operation in highly corrosive environments. A measuring electrode and a magnetic field generating device are designed inside the sensor to determine the flow rate by measuring the induced potential difference generated by the flow of nitric acid in the magnetic field.
2. How it works
The operating principle of the nitric acid flowmeter is based on Faraday's law of electromagnetic induction. When nitric acid flows in a magnetic field, it creates an induced potential difference on the measuring electrode. This induced potential difference is proportional to the flow rate of nitric acid, and by measuring this potential difference, the flow rate of nitric acid can be accurately calculated.
3. Structural characteristics
The structural characteristics of nitric acid flowmeter are mainly reflected in the following aspects:
1) Corrosion-resistant material: The sensor part is made of corrosion-resistant material to adapt to the strong corrosive environment.
2) Accurate measurement: Determine the flow rate by measuring the potential difference, and the measurement accuracy is high.
3) Stable and reliable: the internal structure of the sensor is simple, reasonable design, stable and reliable work.
4) Easy maintenance: the sensor part can be disassembled for easy cleaning and maintenance.
4. Measuring range
The measuring range of the nitric acid flowmeter depends on the specific model and specification, generally covering the flow range from a few milliliters per second to dozens of cubic meters per hour. The user should determine the appropriate model according to the actual required flow range when selecting.
5. Accuracy level
The accuracy level of nitric acid flowmeters is generally divided according to international standards, such as 0.5, 1.0, 1.5 and so on. The accuracy level indicates the accuracy and stability of the measurement results, and the user should choose the appropriate accuracy level according to the actual needs.
6. Installation and commissioning
The installation and commissioning of the nitric acid flowmeter should follow the following steps:
1) Select the appropriate installation position to ensure that the sensor is perpendicular to the fluid flow direction and away from strong magnetic field interference.
2) When installing the sensor, ensure that the sensor is aligned with the pipeline to avoid eddy current and bias.
3) Connect the cable between the sensor and the transmitter to ensure that the connection is reliable and meets safety requirements.
4) Calibrate and debug the flowmeter to ensure accurate measurement. During calibration, standard flowmeters or standard solutions can be used for comparison and adjustment.
7. Use and maintenance
In order to ensure the long-term stable operation of the nitric acid flowmeter, the following use and maintenance work is required:
1) Regularly check the connection of the sensor and cable to ensure its safety and reliability. If it is loose or damaged, it should be fastened or replaced in time.
2) Regularly clean the inner wall and electrode of the sensor to remove dirt and impurities. When cleaning, use the appropriate cleaning agent, and avoid using too rough cleaning tools, so as not to damage the sensor surface.
3) Check the working condition of the converter regularly to ensure its normal operation. If any abnormal situation is found, it should be stopped in time to check and eliminate the fault.
4) Avoid the operation of strong magnetic field interference near the sensor, so as not to affect the measurement accuracy.
8. Fault diagnosis and troubleshooting
When the nitric acid flowmeter fails, it can be diagnosed and eliminated by the following methods:
1) Check the connection of the sensor and cable to ensure that the connection is reliable. If it is loose or damaged, it should be fastened or replaced in time.
2) Check whether there is dirt or impurities on the inner wall and electrode of the sensor, and clean it if necessary. Re-calibrate after cleaning to ensure measurement accuracy.
3) Check the working condition of the converter, if there is an abnormal need to repair or replace. During maintenance, check whether components such as the power supply and circuit board are damaged or aged.
4) If the above methods can not solve the problem, you can contact professionals for further maintenance and debugging. During the maintenance process, care should be taken to protect the sensor and converter parts to avoid further damage.
By following the above methods of use and maintenance, fault diagnosis and elimination, the long-term stable operation of the nitric acid flowmeter can be ensured, and accurate and reliable flow data support can be provided for the production and use of nitric acid.
If you want to know more about the flow meter or flow meter selection, please consult the Aister flow meter manufacturer email: sales@aistermeter.com for help.
Share To:
Previous Post:
Next Post:
News
- Why is the thermal gas mass flowmeter not affected by pressure strength and temperature?
- What to do when a thermal gas mass flow meter fails?
- How are thermal gas mass flow meters used? What are the applications?
- Under what circumstances is the gas measurement need to be regulated compensated vortex flowmeter
- Why Is The Aister Thermal Gas Mass Flowmeter So Popular ?
- Gas turbine flowmeter manufacturers explain their main advantages in measurement
- Gas turbine flowmeter manufacturer Aister instrument field experience summary
- Aister Instrument Empowerment Conference