The vapor flowmeter has no moving parts, strong reliability, high precision, long life, and can measure the instantaneous flow and cumulative flow of liquid in a wide flow range.

Rated 4.6/5 based on 445 customer reviews
Share:
Content

It is not affected by the temperature, pressure, viscosity and composition of the medium, and at the same time, it is not blocked, not stuck, not easy to scale, high temperature resistance, high pressure, safe and explosion-proof, so it is widely used in petroleum, chemical, textile, heating and other occasions that need steam flow meters.

Precautions for the use of steam flowmeter:

1, in the measurement of liquid, be sure to use the flow meter sensor is always completely filled with media, no entrainment of gas;

2, in the instrument upstream and downstream to provide enough straight pipe section and ensure non-curved symmetrical shape, as far as possible in the instrument downstream installation valve;

3, upright installation is usually the first choice, upward swimming fluid can ensure that the instrument is always full tube, and the solid component of the medium can be evenly distributed;

4, if it is possible to produce bubbles, should be gas separator;

5, in the long pipeline easy to vibration installation, should be installed in the flow meter upstream and downstream eliminator;

6. If a valve is installed near the upstream of the sensor installation point, and the valve is constantly switched on and off, the service life of the sensor is greatly affected, and it is very easy to cause thorough damage to the sensor;

7, for steam applications, instrument installation should avoid installation at the bottom of the U-shaped bend, to avoid the phenomenon of water hammer caused by condensation absorption when driving, the strength of the water hammer leads to excessive force on the sensing mechanism, resulting in permanent damage to the sensor;

8, the correct selection of the installation point and the correct installation of the flow meter are very important links, if the installation link error will affect the measurement accuracy, the heavy will affect the service life of the flow meter, and even damage the flow meter;

9, the sensor as far as possible to avoid the overhead very long pipe installation, so after a long time, due to the sag of the sensor is very easy to cause the sensor and flange door seal leakage, if you have to install, must be installed in the upper and lower 2D of the sensor respectively set pipe strong device.