Precession vortex flowmeter requirements for measured airflow conditions

1. The measured gas should be a single-phase, continuous round tube flow through the pipeline.

2, before the gas flows through the flowmeter, its flow rate must be parallel to the pipeline axis, no vortex flow.

3, the air flow should be subsonic, non-pulsating, and its flow rate changes slowly with time.

Rated 5/5 based on 584 customer reviews
Share:
Content

Installation requirements for precession vortex flowmeters

Precession vortex flowmeter does not have too many special requirements for process installation and use environment, but any kind of flow measuring instrument has such a common, That is, as far as possible to avoid vibration and high temperature environment with the flow state interference elements (such as compressors, separators, pressure regulator, small head and manifold, elbow, etc.), keep the instrument front and rear straight pipe wall smooth and straight, to ensure that the measured medium is clean single-phase fluid.

Matters needing attention during installation and use of precession vortex flowmeter

Precession vortex flowmeter without mechanical moving parts, small size, corrosion resistance, stable performance; It can directly display the working pressure, temperature, flow rate and gas volume under standard state of the medium; With the advantages of wide measuring range and small measuring error, it has been widely used in production measurement of oil and gas Wells and sales measurement of natural gas. In the field application for many years, we believe that the flowmeter is suitable for relatively clean dry gas measurement, and gradually become the suitable instrument for small and medium-sized gas measurement.

To ensure accurate metering and reduce metering errors of the precession vortex flowmeter, please note:

1, the selection is reasonable, do not make the actual minimum flow QVmin lower than the lower limit of the flow range of the selected runoff meter.

2, the installation of the correct upstream flow meter should be at least 10D length of the metering straight pipe section. The inner wall of the straight pipe section should be smooth, and there should be no steps, and the weld of the connecting flange should be smoothed, and the flange gasket should not burst into the pipeline. The installation direction of the flowmeter can not be reversed. The test proves that all unreasonable installation will lead to low metering value of the flowmeter.

3, away from the shock source, or on the flow meter, downstream installation pier to avoid the impact of pipeline vibration. Avoid the interference of strong magnetic field on the flowmeter chip.

4, the temperament is relatively clean, especially can not appear liquid gas two-phase flow; When the temperament is dirty, the flowmeter should be cleaned immediately.

5, reduce the impact of air pulsation can be installed in front of the flow meter buffer tank, or extend the length of the metering straight pipe section upstream of the flow meter.

6. Timely metrological verification of the precession vortex flowmeter to ensure accurate and reliable quantity value.