1, pulse vortex flowmeter is a kind of high measurement accuracy, simple installation, small maintenance, a wide range of meters, is currently widely used in petrochemical, metallurgy, textile, urban construction, energy and other industries.
The precession vortex flowmeter is a kind of velocity flow meter, which can be used for the flow measurement of oil, steam, natural gas and other media, and realize the online automatic compensation of dynamic parameters such as pressure, temperature and compression coefficient, which can not only display various parameters on the spot, but also can transmit various signals far out.
Vortex flowmeter is widely used in various industrial environments, in view of some small problems commonly encountered in the installation of vortex flowmeter, Aister gives the following points, hoping to solve the problems encountered in the installation.
In the process of diameter selection of vortex flowmeter, special attention should be paid to the fact that the diameter of vortex flowmeter cannot be selected according to the original pipe diameter on site. The diameter of the vortex flowmeter should be determined according to the parameters in the pipeline such as the flow range of the medium in the pipeline, working temperature and working pressure, and then combined with the technical parameters of the vortex flowmeter.
Vortex flowmeter is widely used because of its wide range, small pressure loss, medium accuracy, linear output, no moving parts, high reliability, small maintenance, medium low price, and relatively high performance price characteristics.
As a very special medium, steam will show special phenomena and problems in the process of vortex flowmeter measurement. The key problem is that the vapor density value deviates too much from the design value, which brings significant measurement errors to the measurement results. At present, the density measuring instrument with mature technology has not been successfully applied, which brings certain difficulties to the steam flow measurement.
Vortex flowmeter is mainly used for the flow measurement of industrial pipeline medium fluids, such as gas, liquid, steam and other media. There are special phenomena and problems in the process of measurement. One of the key problems is that the vapor density value deviates too much from the design value, which brings significant measurement errors to the measurement results. At present, the density measurement instrument with mature technology has not been successfully applied, which brings certain difficulties to the steam flow measurement.
The insertion vortex flowmeter is mainly used for the flow measurement of large-diameter gas, liquid and steam medium in industrial pipelines. In order to ensure the accuracy of its measurement, the following points should be noted when installing:
1. There is fluid flow in the pipeline after power-on, but no signal output
Vortex flowmeter is a velocity flowmeter, which measures the volume flow rate in the working state.
Vortex flowmeter is also known as Karman vortex flowmeter. It is a separation flowmeter made of the principle of natural oscillation of fluid. When a fluid flows at a sufficiently large velocity through an object perpendicular to the direction of the fluid, if the object is of appropriate size, it will produce a neatly aligned and reversed vortex train behind the object along two parallel lines.
Precession vortex flowmeter without mechanical moving parts, small size, corrosion resistance, stable performance; It can directly display the working pressure, temperature, flow rate and gas volume under standard state of the medium; With the advantages of wide measuring range and small measuring error, the precession vortex flowmeter has been widely used in the production measurement of oil and gas Wells and the sales measurement of natural gas.
As a common measuring instrument, precession vortex flowmeter is used frequently. In order to make the flow meter work better, here is to introduce the precautions for its installation.
Thermal gas mass flowmeter, gas flow measurement without temperature and pressure compensation, measurement is convenient and accurate.
Thermal gas mass flowmeter due to its various advantages and characteristics, now has been widely used in various industries flow measurement, in the actual measurement of thermal gas flow meter technical advantages are more and more obvious, the following we on the thermal gas mass flowmeter application occasions and some of their own technical advantages do some introduction, hope to be useful to you:
The thermal gas flowmeter adopts the principle of thermal diffusion, and the thermal diffusion technology is a technology with excellent performance and high reliability under harsh conditions. Typical sensing elements of thermal gas mass flowmeters include two thermal resistors (PT100), one is a speed sensor and one is a temperature sensor that automatically compensates for changes in gas temperature.
The characteristics and installation and maintenance methods of precession vortex flow meter
The thermal gas mass flowmeter is an instrument that uses the principle of heat conduction to measure flow. The instrument adopts constant temperature difference method for gas mass flow sensor part consists of two reference platinum resistance temperature sensors. Using a bridge loop, one sensor measures the flow temperature and the other maintains a constant temperature difference above the fluid temperature, allowing flow measurement under high temperature and high pressure conditions.