1. Vibration effect
Compressed air is generated by air compressor or high pressure fan. When these devices are in operation, they all have varying degrees of vibration, and sometimes the vibration is relatively strong, and this vibration is transmitted through the connecting pipe. When selecting and determining the position of the vortex flowmeter, this influencing factor should be fully considered. In various detection methods, the anti-vibration performance of the instrument is not the same due to different detection components. For the vortex street of the detection element, the vibration resistance can reach 0.5~1G. When determining the installation position of the vortex flowmeter, it should be as far away from the power equipment such as air compressors and fans as possible.